What is Involved in an Electrical Safety Audit, The basics of any ES audit will cover the following topics, A typical small to medium sized location can complete a thorough electrical safety audit in one day, with sometime taken up that evening for report writing as required. A larger facility may take two to three days for an audit, especially at sites that have an unusually large number of electrical employees (150 or more). The process involves a full review of electrical program records, including training schedule, qualification, electrical maintenance, and self assessments. Atypical audit report ranges from five pages to upwards of thirty pages for a larger facility. Envision, Set Scope, Frequency and Types of Audits, In order to manage the incident investigations, an organizational policy is the first step. This document should identify the following, toper form the audit, including audit documentation, appropriate checklists, and a format for the written report. Include a site periodicity for the electrical safety audit, and be sure to schedule required personnel to conduct the audit efficiently. Electrical Safety Audit is examining the security of electrical installations of any industrial unit or organization. Electrical Safety Audit is performed by enquiry, inspection, testing and verification. Electrical Safety Audits are conducted by experienced professionals who assist clients in reducing risk and help to ensure compliance with applicable Safety Standards and Regulations. Electrical Safety Audit Benefits, Preventive Maintenance, It helps in identifying the problem which can lead to potential hazard, Safety of Man and machine, Electrical safety audits ensure safety of your Man and machine. Compliance, It has become mandatory in various sectors to undergo Electrical safety Audit after a specified time span. Effective Operation and Maintenance, A timely energy audits identifies the upcoming issues and its recommendations we ensures and effective Operation and maintenance of the system. Energy Saving, Overheating is the major problem in the electrical network which leads to power losses. You can safe energy by timely Electrical safety Audit, Our auditors follow a scientific approach for evaluating potential electrical hazards and produce reports recommending actions for improvement in Electrical Safety Instalments. Electrical Safety Audits helps in identifying, Electrical hazards to reduce the risk of accidents like fire because of short circuiting, Areas of risk or vulnerability in electrical systems and installations, Noncompliance with the legislation and best practices. Electrical Safety Audits include factory assessment of electrical installations within the various industries like Electrical, Construction, in Cities in India. Our Electrical Safety Audit indicates organizations adherence to safe Electrical Installation, use of ordinary operating procedures of electrical intensive equipment and following Electrical Safety Standards and as truly Auditing Firm, offers Value Auditing Services in Safety Auditing by ensuring and suggesting Safety Measures. Auditing Services of CDG are designed to satisfy Global Standards that deliver Credibility in adoption of Energy Saving Measures. to realize this objective, professionally trained auditors are deputed to spot Opportunities and Measures for Improvements in Electrical Safety Auditing. Scope for Electrical Safety Audit, Electrical Safety Audit reviews the degree of safety of the electrical system within the premises, providing recommendation and measures to be taken to reduce or eliminate the danger of electrical hazards. Following is that the scope in detail, Review of the electrical hazards identification and risk assessment. Review of the earthing and lightning protection system implemented in plant to make sure the equipment and human safety. To check earth resistance of earth pits and sockets on sampling basis. Review of EPM (Electrical Preventive Maintenance) programme within the facility Review of the shutdown procedure, work permits, lockout tags etc. To check the hotspot within the electrical installation and equipment by using thermal imager. Review of the electrical distribution network and system of the plant emphasizing on adequacy and functionality of protection devices. Review of the electrical documents like register of electrical installations, single line diagrams, test records(Transformer oil test, Insulation Resistance test and Earth Resistance tests)and data sheets of critical electrical installations. Review of the supply and reliability of emergency systems like DG set, UPS, battery etc. Review of the records of coaching and competency of employee and contractor performing the trade.

 

Enter Buying Requirement Details
Email Id
Mobile number


Back to top